★ Optional RS-232 to USB cable
(0℃~40℃) |
PPA400-80 |
|||
Rated Output |
Voltage |
0~80.5V |
||
Current |
0~20.5A |
|||
Power |
0~400W |
|||
Power ratio |
4.12 |
|||
Line regulation |
Voltage |
≤0.01%+2.5mV |
||
Current |
≤0.1%+2.5mA |
|||
Load regulation |
Voltage |
≤0.01%+5mV |
||
Current |
≤0.1%+5mA |
|||
Setting accuracy |
Voltage |
±(0.01% of reading + 10mV) |
||
Current |
±(0.1% of reading + 10mA) |
|||
Setting resolution |
Voltage |
1mV |
||
Current |
1mA |
|||
Reading accuracy |
Voltage |
±(0.01% of reading +5mV) |
||
Current |
±(0.1% of reading + 0.1% of FS) |
|||
Reading resolution |
Voltage |
1mV |
||
Current |
1mA |
|||
Ripple&Noise (20Hz-20MHz) |
Voltage |
≤50mVpp |
||
Current |
≤15mArms |
|||
Rise time |
Empty load |
≤300ms |
||
Full load |
≤1s |
|||
Fall time |
Empty load |
≤500ms |
||
Full load |
≤300ms |
|||
Slew rate |
Time range |
0.2~99999S, resolution 0.1S |
||
Rise slew rate |
0.3V/ms(max) |
|||
Fall slew rate |
0.3V/ms(max) |
|||
Recovery time |
≤5ms (50% load change) |
|||
Temp. co-efficiency |
≤100ppm |
|||
Efficiency |
80% typical |
|||
Power factor |
0.99 typical |
|||
Protection |
Over load, over voltage, over current, over temperature and reverse polarity protections |
|||
O.V.P setting range |
0.1~90V |
|||
O.C.P setting range |
0.1~22A |
|||
Remote sense function |
Maximum compensation voltage 1V |
|||
Battery charge |
Lithium battery curve charge |
|||
Interface |
RS232 & RS485 interface, Support SCPI & ModBus commands |
|||
External trigger |
Through 2-pin terminal |
|||
Memory |
300 sets |
|||
Insulation |
Between base and terminals: ≥100MΩ/500VDC |
|||
Operating environment |
Indoor use |
Altitude: ≤2000m |
Ambient temperature: 0~40℃ |
|
Relative humidity: ≤80% |
Installation category: II |
Pollution degree: 2 |
||
Storage environment |
-10℃~70℃, ≤70%RH |
|||
Power source |
AC 176V~264V(full load), 90V~132V(half load), 47~63Hz |
|||
Accessories |
Power cord x1, Operation manual x1, RS232 cable x1, Software CD x1 |
|||
Dimension |
215Wx89Hx352D mm |
|||
Weight |
5kg |
Model |
Output Voltage |
Output Current |
O.V.P. |
O.C.P. |
Resolution |
Dimension |
Weight |
PPA400-80 |
0~80.5V |
0~20.5A |
0.1~90V |
0.1~22A |
1mV/0.1mA |
215Wx89Hx352D mm |
2.5kg |