- Home
- Products
- DC Power Supplies
- High Power Programmable DC Power Supplies
- PCL600_1200_Series
Programmable Switch Mode DC Power Supply
★ Adopting ZVZCS PWM technology, high efficiency and high stability
★ 4 1/2 digits LED display for voltage and current
★ Max.rated output 600W to 9KW
★ Max.rated voltage from 6V to 600V, max.rated current from 2A to 300A
★ Constant voltage and constant current operations, auto CV/CC switch
★ Built into 19-inch standard chassis
★ Thermostatic control fan, low noise
★ Low ripple, high stability
★ No overshoot during startup
★ List mode function, Auto Run function
★ Preset function, setting of voltage and current with output open circuit
★ Front panel operation: preset voltage and current, output ON/OFF
★ Multiple protections: OVP, OTP, UVP and current limit protections
★ Multiple programming interfaces: RS232, RS485 and RS422
★ Support ModBus-RTU commands
Specifications
Output |
||
Rated Voltage |
DC 0~100% full range adjustable |
|
Rated Current |
DC 0~100% full range adjustable |
|
OVP Range |
DC 0~105% of rated voltage adjustable |
|
Line Regulation |
CV≤0.1%+2LSB, CC≤0.2%+2LSB |
|
Load Regulation |
CV≤0.1%+2LSB, CC≤0.1%+2LSB |
|
Ripple & Noise |
≤50mV / 100mV / 200mV |
|
Programming |
||
Programming Resolution |
Voltage |
0.001V / 0.01V/ 0.1V |
Current |
0.001A / 0.01A/ 0.1A |
|
OVP |
0.001V / 0.01V/ 0.1V |
|
Interface |
RS232, RS485 and RS422 |
|
Commands |
ModBus-RTU |
|
Display |
||
Meter |
4 1/2 digits LED display for voltage and current |
|
Display Resolution |
Voltage |
0.001V / 0.01V/ 0.1V |
Current |
0.001A / 0.01A/ 0.1A |
|
Display Accuracy |
Voltage |
≤0.2%FS+2LSB |
Current |
≤0.5%FS+2LSB |
|
Protection |
||
Over Voltage Protection (O.V.P.) |
Built-in OVP protection with limit of 105% rated output voltage. The output will be shut down when OVP is activated. |
|
Over Temperature Protection (O.T.P.) |
Built-in OTP protection with heat sink temperature limit of 50℃±5%. The output will be shut down when OTP is activated. |
|
Under Voltage Protection (U.V.P.) |
Built-in UVP protection with limit of 165Vac. The output will be shut down when UVP is activated. |
|
General |
||
Cooling method |
Cooling fan |
|
Operating environment |
0℃~40℃, 10%~80%RH |
|
Storage environment |
-20℃~70℃, 10%~90%RH |
Model |
Output Voltage |
Output Current |
O.V.P. |
Resolution |
600W models, size 213Wx88Hx340D mm (1/2 2U) |
||||
PCL600-1H |
0~100V |
0~6A |
0~105V |
100mV/1mA |
PCL600-150 |
0~150V |
0~4A |
0~157.5V |
100mV/1mA |
PCL600-2H |
0~200V |
0~3A |
0~210V |
100mV/1mA |
PCL600-3H |
0~300V |
0~2A |
0~310V |
100mV/1mA |
PCL600-4H |
0~400V |
0~1.5A |
0~420V |
100mV/1mA |
PCL600-5H |
0~500V |
0~1.2A |
0~525V |
100mV/1mA |
1200W models, size 213Wx88Hx340D mm (1/2 2U) |
||||
PCL1200-6S |
0~6V |
0~200A |
0~6.3V |
1mV/100mA |
PCL1200-12S |
0~12V |
0~100A |
0~12.6V |
10mV/100mA |
PCL1200-15S |
0~15V |
0~80A |
0~15.75V |
10mV/10mA |
PCL1200-30S |
0~30V |
0~40A |
0~31.5V |
10mV/10mA |
PCL1200-60S |
0~60V |
0~20A |
0~63V |
10mV/10mA |
PCL1200-1HS |
0~100V |
0~12A |
0~105V |
100mV/10mA |
PCL1200-150S |
0~150V |
0~8A |
0~157.5V |
100mV/1mA |
PCL1200-2HS |
0~200V |
0~6A |
0~210V |
100mV/1mA |
PCL1200-3HS |
0~300V |
0~4A |
0~315V |
100mV/1mA |
PCL1200-4HS |
0~400V |
0~3A |
0~420V |
100mV/1mA |
PCL1200-5HS |
0~500V |
0~2.4A |
0~525V |
100mV/1mA |
PCL1200-6HS |
0~600V |
0~2A |
0~630V |
100mV/1mA |
Download Details |
||
Catalog |
|