Programmable Switch Mode DC Power Supplies
★ Max.output voltage 5000V, Max. output current 10000A
★ Applying IGBT module and 19-inch standard size
★ 4 digits LCD display for voltage, current, power and load resistance
★ Constant voltageand constant currentoperations, auto CV/CC switch
★ Front panel operation: preset voltage and current, output ON/OFF
★ Multiple protections: OVP, OCP, OTP and OLP
★ Communication: RS-232 and RS-485 interface
★ Optional function
– Remote control: 0-5V, 0-10V or 4-20mA signal to control output voltage and current
– Remote Sensing: compensate the voltage drop
– Remote ON/OFF control: using a replay to control the output
– Timer Switch: turn on or off the output as per preset time
– Square Waveform Output: output square waveform according to preset time and cycles
– Reverse polarity protection: to protect power supply from damage by reverse current from EUT
– PV curve output for solar panel tests
★ Customized specifications and functions acceptable
Working mode |
IGBT |
Input |
3φ4W, 380V±10% 50Hz/60Hz |
Constant Voltage Operation |
|
Output voltage |
DC 0~100% full range adjustable |
Line regulation |
≤0.3%FS rms |
Load regulation |
≤0.5%FS rms |
Ripple & Noise |
≤0.3%FS+10mVrms |
Time drift |
≤0.5%FS rms |
Temperature drift |
≤0.1%FS rms/℃ |
Setting accuracy |
±(0.5% FS +50mV) (25±5℃) |
Constant Current Operation |
|
Output Current |
DC 0~100% full range adjustable |
Line regulation |
≤0.3%FS rms |
Load regulation |
≤0.5%FS rms |
Ripple & Noise |
≤0.5%FS+10mVrms |
Time drift |
≤1%FS rms |
Temperature drift |
≤0.3%FS rms/℃ |
Setting accuracy |
±(0.5% FS +3 digits) (25±5℃) |
Display |
|
Voltmeter |
4 digits LCD display |
Ammeter |
4 digits LCD display |
Voltage resolution |
0.000V-9.999V; 0.00V-99.99V; 0.0V-999.9V; 0V-9999V |
Current resolution |
0.000A-9.999A; 0.00A-99.99A; 0.0A-999.9A; 0A-9999A |
Reading accuracy |
±(0.5% FS +3 digits) (25±5℃) |
Protection |
|
Over Voltage Protection (O.V.P.) |
Built-in OVP protection with limit of 110% rated voltage. The output will be shut down when OVP is activated. |
Over Current Protection (O.C.P.) |
Built-in OCP protection with limit of 110% rated current. The output will be shut down when OCP is activated. |
Over Temperature Protection (O.T.P.) |
Built-in OTP protection with heat sink temperature limit of 80℃±5%. The output will be shut down when OTP is activated. |
General |
|
Cooling method |
Air cool |
Operating environment |
0℃~40℃, 10%~80%RH |
Storage environment |
-20℃~70℃, 10%~90%RH |
Input module |
Power socket or terminal block |
Accessories |
Operation manual: 1EA |
Model |
Rated voltage |
Rated current |
Rated Power |
Input Voltage |
PWD5-2000 |
0~5V |
0~2000A |
10KW |
3P 380Vac |
PWD5-3000 |
0~5V |
0~3000A |
15KW |
3P 380Vac |
PWD5-5000 |
0~5V |
0~5000A |
25KW |
3P 380Vac |
PWD10-1000 |
0~10V |
0~1000A |
10KW |
3P 380Vac |
PWD10-2000 |
0~10V |
0~2000A |
20KW |
3P 380Vac |
PWD10-3000 |
0~10V |
0~23000A |
30KW |
3P 380Vac |
PWD15-2000 |
0~15V |
0~2000A |
30KW |
3P 380Vac |
PWD15-3000 |
0~15V |
0~3000A |
45KW |
3P 380Vac |
PWD15-4000 |
0~15V |
0~4000A |
60KW |
3P 380Vac |
PWD30-600 |
0~30V |
0~600A |
18KW |
3P 380Vac |
PWD30-1000 |
0~30V |
0~1000A |
30KW |
3P 380Vac |
PWD30-1000 |
0~30V |
0~1000A |
30KW |
3P 380Vac |
PWD50-500 |
0~50V |
0~500A |
25KW |
3P 380Vac |
PWD50-600 |
0~50V |
0~600A |
30KW |
3P 380Vac |
PWD50-1000 |
0~50V |
0~1000A |
50KW |
3P 380Vac |
PWD50-3000 |
0~50V |
0~3000A |
150KW |
3P 380Vac |
PWD60-1000 |
0~60V |
0~1000A |
60KW |
3P 380Vac |
PWD100-600 |
0~100V |
0~600A |
60KW |
3P 380Vac |
PWD100-1000 |
0~100V |
0~1000A |
100KW |
3P 380Vac |
PWD250-100 |
0~250V |
0~100A |
25KW |
3P 380Vac |
PWD300-100 |
0~300V |
0~100A |
30KW |
3P 380Vac |
PWD300-1000 |
0~300V |
0~1000A |
300KW |
3P 380Vac |
PWD600-30 |
0~600V |
0~30A |
18KW |
3P 380Vac |
PWD600-50 |
0~600V |
0~50A |
30KW |
3P 380Vac |
PWD1000-20 |
0~1000V |
0~20A |
20KW |
3P 380Vac |
PWD2000-10 |
0~2000V |
0~10A |
20KW |
3P 380Vac |
PWD2000-20 |
0~2000V |
0~20A |
40KW |
3P 380Vac |
PWD3000-10 |
0~3000V |
0~10A |
30KW |
3P 380Vac |
Download Details |
|
Data sheet |