Product No : PCH600S_Series
Product Description

The PCH series are high power output Switching DC power supply with rated power from 600W toW. The PCH series adopts ZVZCS PWM technology, which greatly reduces switching consumption and therefore facilitates switching function with high efficiency and high stability. The PCH series are built into a 2U 19-inch standard chassis. The maximum rated voltage is from +1000V to +12KV.

  • remoto_sense.jpg
  • 1mA.jpg
  • CE.jpg
  • labview.jpg
  • RS485.jpg
  • RS232.jpg

★ Adopting ZVZCS PWM technology, high efficiency and high stability

★ 4 1/2 digits LED display for voltage and current

★ Max.rated output 600W to 5KW

★ Max.rated voltage from +1000V to +12KV

★ Option for negative output from -1000V to -12KV

★ Constant voltage and constant current operations, auto CV/CC switch 

★ Built into 2U 19-inch standard chassis

★ Thermostatic control fan, low noise

★ Low ripple, high stability

★ No overshoot during startup

★ List mode function, Auto Run function

★ Preset function, setting of voltage and current with output open circuit

★ Front panel operation: preset voltage and current, output ON/OFF

★ Multiple protections: OVP, OTP, UVP and current limit protections

★ Multiple programming interfaces: RS232, RS485 and RS422

★ Support ModBus-RTU commands

Specifications

 

Output

Rated Voltage

Full range adjustable

Rated Current

Full range adjustable

OVP Range

Up to 105% of rated voltage adjustable

Line Regulation

CV≤0.5%+2LSB, CC≤0.5%+2LSB

Load Regulation

CV≤0.1%+2LSB, CC≤0.1%+2LSB

Ripple & Noise

≤0.05% FS, ≤0.1% FS

Programming

Programming Resolution

Voltage

1V

Current

0.1mA/ 1mA

OVP

1V

Interface

RS232, RS485 and RS422

Commands

ModBus-RTU

Display

Meter

4 1/2 digits LED display for voltage and current

Display Resolution

Voltage

1V

Current

0.1mA/ 1mA

Display Accuracy

Voltage

≤0.2%FS+2LSB

Current

0.5%FS+2LSB

Protection

Over Voltage Protection (O.V.P.)

Built-in OVP protection with limit of 105% rated output voltage.

The output will be shut down when OVP is activated.

Over Temperature Protection (O.T.P.)

Built-in OTP protection with heat sink temperature limit of 50±5%.

The output will be shut down when OTP is activated.

Under Voltage Protection

(U.V.P.)

Built-in UVP protection with limit of 165Vac.

The output will be shut down when UVP is activated.

General

Cooling method

Cooling fan

Operating environment

0~40, 10%~80%RH

Storage environment

-20~70, 10%~90%RH

Model

Output Voltage

Output Current

O.V.P.

Resolution

Compact size 600W models, size 213Wx88Hx340D mm (1/2 2U)

PCH600-10HS

0~1000V

0~600mA

0~1050V

1V/0.1mA

PCH600-12HS

0~1200V

0~500mA

100~1260V

1V/0.1mA

PCH600-15HS

0~1500V

0~600mA

100~1575V

1V/0.1mA

PCH600-20HS

0~2000V

0~600mA

200~2100V

1V/0.1mA

PCH600-30HS

200~3000V

0~200mA

200~3150V

1V/0.1mA

Download Details

Catalog

Twintex_Catalog_PCH