- Home
- Products
- Discontinued Products
- TP-D_Series(7kW-15kW)
Programmable Switching DC Power Supplies
★ Max.output voltage 3000V, Max. output current 3000A
★ Applying IGBT module and 19-inch standard size
★ 4 1/2 LED display for voltage and current
★ Constant voltage (CV) and constant current (CC) operations, Auto CV/CC switch
★ Front panel operation: preset voltage and current, output ON/OFF
★ Multiple protections: OVP, OCP, OTP and OLP
★ Optional function
– Communication: RS-232 or RS485 interface
– Remote control: 0-5V, 0-10V or 4-20mA signal to control output voltage and current
– Remote Sensing: to compensate the voltage drop
– Remote ON/OFF control: using a potentiometer to control the output
– Timer Switch: to turn on or off the output as per preset time
– Square Waveform Output: to output user-defined square waveform according to preset time and cycles
– Reverse polarity protection: to protect power supply from damage by reverse current from EUT
★ Customized specifications and functions acceptable
Working mode |
IGBT |
Input |
220V±10%, 50/60Hz ≥10KW: three phase 380Vac±10% |
Constant Voltage Operation |
|
Output voltage |
DC 0~100% full range adjustable |
Line regulation |
≤0.2% + 2d |
Load regulation |
≤0.3% + 2d |
Temperature drift |
≤0.03%/℃ |
Ripple & Noise |
≤0.3%+10mV (rms) |
Constant Current Operation |
|
Output Current |
DC 0~100% full range adjustable |
Line regulation |
≤0.2% + 2d |
Load regulation |
≤0.3% + 2d |
Temperature drift |
≤0.03%/℃ |
Ripple & Noise |
≤0.5%+10mA (rms) |
Display |
|
Meter |
4 1/2 digits LED display |
Voltage display |
00.00V-19.99V; 000.0V-199.9V; 0000V-1999V |
Current resolution |
00.00A-19.99A; 000.0A-199.9A; 0000A-1999A |
Accuracy |
± (1% reading +1 digit) |
Protection |
|
Over Voltage Protection (OVP) |
Built-in OVP, protection limit is +5% of rated voltage. The output will be shutdown when OVP is activated. |
Over Current Protection (OCP) |
Over load, short circuit and current limit output |
Over Temperature Protection (OTP) |
Built-in OTP, protection limit is 85℃±5% (temperature of cooling device). The output will be shutdown when OTP is activated. |
General |
|
Cooling method |
Cooling fan |
Input module |
Power socket or terminal block |
Operating environment |
0℃~40℃, 10%~80%RH |
Storage environment |
-20℃~70℃, 10%~90%RH |
Accessory List |
High Power DC Power Supply Selection Guide |
||||||
Model |
Output Voltage |
Output Current |
Output Capacity |
Weight kg |
Dimension WxHxD, mm |
|
TP10-10HD |
0~10V |
0~1000A |
10KW |
70 |
425*300*610 |
|
TP15-6HD |
0~15V |
0~600A |
9KW |
60 |
425*300*610 |
|
TP15-8HD |
0~15V |
0~800A |
12KW |
80 |
425*300*610 |
|
TP30-3HD |
0~30V |
0~300A |
9KW |
60 |
425*300*610 |
|
TP30-4HD |
0~30V |
0~400A |
12KW |
80 |
425*300*610 |
|
TP50-150D |
0~50V |
0~150A |
7.5KW |
40 |
425*300*610 |
|
TP50-2HD |
0~50V |
0~200A |
10KW |
70 |
425*300*610 |
|
TP50-250D |
0~50V |
0~250A |
12.5KW |
80 |
425*300*610 |
|
TP60-150D |
0~60V |
0~150A |
9KW |
60 |
425*300*610 |
|
TP60-2HD |
0~60V |
0~200A |
12KW |
80 |
425*300*610 |
|
TP1H-1HD |
0~100V |
0~100A |
10KW |
70 |
425*300*610 |
|
TP150-50D |
0~150V |
0~50A |
7.5KW |
40 |
425*132*502 |
|
TP150-60D |
0~150V |
0~60A |
9KW |
60 |
425*132*502 |
|
TP150-80D |
0~150V |
0~80A |
12KW |
80 |
425*300*610 |
|
TP2H-50D |
0~200V |
0~50A |
10KW |
70 |
425*300*610 |
|
TP250-30D |
0~250V |
0~30A |
7.5KW |
40 |
425*132*502 |
|
TP250-40D |
0~250V |
0~40A |
10KW |
70 |
425*300*610 |
|
TP250-50D |
0~250V |
0~50A |
12.5KW |
80 |
425*300*610 |
|
TP3H-30D |
0~300V |
0~30A |
9KW |
60 |
425*132*502 |
|
TP3H-40D |
0~300V |
0~40A |
12KW |
80 |
425*300*610 |
|
TP4H-30D |
0~400V |
0~30A |
12KW |
80 |
425*300*610 |
|
TP6H-20D |
0~600V |
0~20A |
12KW |
80 |
425*300*610 |
|
TP10H-10D |
0~1000V |
0~10A |
10KW |
70 |
425*300*610 |
|
TP10-10HD |
0~10V |
0~1000A |
10KW |
70 |
425*300*610 |
|
Download Details |
||
Data sheet |
|
|
Catalog |
|
|
Operation manual |