Product No : PCL4000_5000W系列

Output

Rated Voltage

DC 0~100% full range adjustable

Rated Current

DC 0~100% full range adjustable

OVP Range

DC 0~105% of rated voltage adjustable

Line Regulation

CV≤0.1%+2LSB, CC≤0.2%+2LSB

Load Regulation

CV≤0.1%+2LSB, CC≤0.1%+2LSB

Ripple & Noise

50mV / 100mV / 200mV

Programming

Programming Resolution

Voltage

0.001V / 0.01V/ 0.1V

Current

0.001A / 0.01A/ 0.1A

OVP

0.001V / 0.01V/ 0.1V

Interface

RS232, RS485 and RS422

Commands

ModBus-RTU

Display

Meter

4 1/2 digits LED display for voltage and current

Display Resolution

Voltage

0.001V / 0.01V/ 0.1V

Current

0.001A / 0.01A/ 0.1A

Display Accuracy

Voltage

≤0.2%FS+2LSB

Current

0.5%FS+2LSB

Protection

Over Voltage Protection (O.V.P.)

Built-in OVP protection with limit of 105% rated output voltage.

The output will be shut down when OVP is activated.

Over Temperature Protection (O.T.P.)

Built-in OTP protection with heat sink temperature limit of 50±5%.

The output will be shut down when OTP is activated.

Under Voltage Protection

(U.V.P.)

Built-in UVP protection with limit of 165Vac.

The output will be shut down when UVP is activated.

General

Cooling method

Cooling fan

Operating environment

0~40, 10%~80%RH

Storage environment

-20~70, 10%~90%RH