- AHV 15kV 200mA 3000W series High Voltage AC power supply
- 4 digits LED display for voltage, current and frequency
- Rated output AC 15kV (30kVpp) 200mA 3000W
- Fixed frequency 1kHz, 2kHz, 3kHz, 4kHz, 8kHz, 5kHz, 10kHz, 20kHz, 30kHz, 40kHz, 50kHz, 100kHz
- Adjustable frequency 2kHz to 100kHz
- Other voltage, frequency and power range at request
Description
Corona discharge applications utilize ionized gas (plasma) for surface treatment, pollution control, and industrial processing. The corona plasma is generated by the application of high voltage pulses.
AHV 15kV 200mA series high voltage AC power supply provides high-frequency and high-stability outputs at 15kV (30kV peak to peak) for surface modification, including corona treatment and electrostatic processing. 15kV is sufficient for high-efficiency corona discharge, generally at frequency of 8kHz to 30kHz.
AHV 15kV 200mA series high voltage AC power supply is available with a wider frequency range, with different options from 1kHz to 100kHz either at a fixed frequency or an adjustable frequency range.
Options of fixed frequency range: 1kHz, 2kHz, 3kHz, 4kHz, 5kHz, 8kHz, 10kHz, 20kHz, 30kHz, 40kHz, 50kHz, 100kHz
Options of adjustable frequency range: 2kHz ~ 8kHz; 5kHz ~ 10kHz; 10kHz ~ 20kHz; 10kHz ~ 30kHz; 20kHz ~ 30kHz; 20kHz ~ 40kHz; 20kHz ~ 50kHz; 30kHz ~ 40kHz; 30kHz ~ 50kHz; 50kHz ~ 100kHz
Corona discharge has a wide range of practical applications that exploit its ability to generate ions, ozone, UV light, and charged aerosols. Key applications include:
AHV 15kV 200mA series high voltage AC power supply provides high-frequency and high-stability outputs at 15kV (30kV peak to peak) for surface modification, including corona treatment and electrostatic processing. 15kV is sufficient for high-efficiency corona discharge, generally at frequency of 8kHz to 30kHz.
AHV 15kV 200mA series high voltage AC power supply is available with a wider frequency range, with different options from 1kHz to 100kHz either at a fixed frequency or an adjustable frequency range.
Options of fixed frequency range: 1kHz, 2kHz, 3kHz, 4kHz, 5kHz, 8kHz, 10kHz, 20kHz, 30kHz, 40kHz, 50kHz, 100kHz
Options of adjustable frequency range: 2kHz ~ 8kHz; 5kHz ~ 10kHz; 10kHz ~ 20kHz; 10kHz ~ 30kHz; 20kHz ~ 30kHz; 20kHz ~ 40kHz; 20kHz ~ 50kHz; 30kHz ~ 40kHz; 30kHz ~ 50kHz; 50kHz ~ 100kHz
Corona discharge has a wide range of practical applications that exploit its ability to generate ions, ozone, UV light, and charged aerosols. Key applications include:
- Air and gas treatment: used in gas purification and particulate charging for collection; used in industrial and laboratory ozone generation for odor removal, disinfection, and chemical oxidation (water treatment, VOC removal in air streams).
- Surface treatment and materials processing: used in polymer surface activation to surface energy of plastics and films before printing, coating, or bonding; used in Ozone/UV-assisted surface cleaning and sterilization to remove organic contaminants and promotes chemical functionalization.
- Electrostatic processes: used in electrostatic precipitation in power plants and industrial boilers; used in electrostatic coating and printing to improve substrate wettability (corona treatment of polymers for better ink/adhesive adhesion).
- Electronics and HV engineering: used in partial discharge testing and diagnostics to locate insulation defects in cables, transformers, and HV equipment; used in high-voltage corona rings and shielding to control discharge location and reduce electromagnetic interference (EMI).
Specification
AHV 15kV 200mA High Voltage AC Power Supply for Corona Discharge Applications
| Model (15kV) | Peak Voltage | Max Current | Power | Frequency |
| AHV15-200-FF1K | 0~15kV | 0~200mA | 3000W | Fixed 1kHz |
| AHV15-200-FF2K | 0~15kV | 0~200mA | 3000W | Fixed 2kHz |
| AHV15-200-FF3K | 0~15kV | 0~200mA | 3000W | Fixed 3kHz |
| AHV15-200-FF4K | 0~15kV | 0~200mA | 3000W | Fixed 4kHz |
| AHV15-200-FF5K | 0~15kV | 0~200mA | 3000W | Fixed 5kHz |
| AHV15-200-FF8K | 0~15kV | 0~200mA | 3000W | Fixed 8kHz |
| AHV15-200-FF10K | 0~15kV | 0~200mA | 3000W | Fixed 10kHz |
| AHV15-200-FF20K | 0~15kV | 0~200mA | 3000W | Fixed 20kHz |
| AHV15-200-FF30K | 0~15kV | 0~200mA | 3000W | Fixed 30kHz |
| AHV15-200-FF40K | 0~15kV | 0~200mA | 3000W | Fixed 40kHz |
| AHV15-200-FF50K | 0~15kV | 0~200mA | 3000W | Fixed 50kHz |
| AHV15-200-FF100K | 0~15kV | 0~200mA | 3000W | Fixed 100kHz |
| AHV15-200-AF2-8K | 0~15kV | 0~200mA | 3000W | Adjustable 2kHz to 8kHz |
| AHV15-200-AF5-10K | 0~15kV | 0~200mA | 3000W | Adjustable 5kHz to 10kHz |
| AHV15-200-AF10-20K | 0~15kV | 0~200mA | 3000W | Adjustable 10kHz to 20kHz |
| AHV15-200-AF10-30K | 0~15kV | 0~200mA | 3000W | Adjustable 10kHz to 30kHz |
| AHV15-200-AF10-40K | 0~15kV | 0~200mA | 3000W | Adjustable 10kHz to 40kHz |
| AHV15-200-AF10-50K | 0~15kV | 0~200mA | 3000W | Adjustable 10kHz to 50kHz |
| AHV15-200-AF20-30K | 0~15kV | 0~200mA | 3000W | Adjustable 20kHz to 30kHz |
| AHV15-200-AF20-40K | 0~15kV | 0~200mA | 3000W | Adjustable 20kHz to 40kHz |
| AHV15-200-AF20-50K | 0~15kV | 0~200mA | 3000W | Adjustable 20kHz to 50kHz |
| AHV15-200-AF30-40K | 0~15kV | 0~200mA | 3000W | Adjustable 30kHz to 40kHz |
| AHV15-200-AF30-50K | 0~15kV | 0~200mA | 3000W | Adjustable 30kHz to 50kHz |
| AHV15-200-AF50-100K | 0~15kV | 0~200mA | 3000W | Adjustable 50kHz to 100kHz |
| Dimensions | 439W*133H*563D mm | |||
| Weight | Approx. 20kg | |||
| AC input | 1φ3W, 220V±10% 50/60Hz | |||